Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2021, 09:39 AM
  • C 0372_C 0371_04152021_030432.mp4

Date
04/15/2021
W/O
886146
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00141
PipeID
P09835
Time
2:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8729
Sewer Name
C JOINT OUTFALL C - UNIT 8C
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_886146_TV19080_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
78 in.
Upstream MH
C 0372
Downstream MH
C 0371
Dir. of Survey
Downstream
Length Surveyed
580.9 ft.
Total Length
580.9 ft.
Structural Index
3
Structural Quick
3V00
Structural Rating
345
O&M Index
4
O&M Quick
4300
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
357
Pipe schematic from manhole C 0372 to C 0371
MH: C 0372MH: C 0371downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 03720 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 25 %of cross sectional area4.2 ft. MGO - General Observation - MAG COAT4.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start199.3 ft. IR - Infiltration Runner, from 01 to 04 o'clock, within 8 inches of joint: YES309.4 ft. IR - Infiltration Runner, from 02 to 04 o'clock, within 8 inches of joint: YES394.7 ft. IR - Infiltration Runner, at 10 o'clock, within 8 inches of joint: YES580.9 ft. AMH - Downstream Manhole, Survey Ends - C 0371580.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK580.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Runner, from 01 to 04 o'clock, within 8 inches of joint: YES

    199.3 ft. - Infiltration Runner, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 02 to 04 o'clock, within 8 inches of joint: YES

    309.4 ft. - Infiltration Runner, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 10 o'clock, within 8 inches of joint: YES

    394.7 ft. - Infiltration Runner, at 10 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0AMHC 0372
199.3IR
4.2MGOMAG COAT
580.9AMHC 0371
580.9MGOCONNECTION AT THE MH 9 OC'LOCK
580.9SAP
4.2SAP
0MWL
394.7IR
0MGOCONNECTION AT THE MH 3 OC'LOCK
309.4IR
0MWM

Properties (8)

additional_info
630074041421202
custom_field_three
AGGREGATE PROJECTING/INFILTRATION
custom_field_two
3
customer
1
datetime
2021-04-15T02:39:12-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26760