Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2021, 07:11 AM
  • C 0699_C 0698_03232021_022040.mp4

Date
03/23/2021
W/O
880421
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00117
PipeID
P26270
Time
12:11 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8665
Sewer Name
C JOINT OUTFALL C - UNIT 1 RELIEF
City
WILMINGTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
16
Purpose
Routine Assessment
Project
WO_880421_TV08182_MAR2021
Sewer Type
Gravity
Material
RGRCP-PTL
Shape
Square
Height
90 in.
Width
90 in.
Upstream MH
C 0699
Downstream MH
C 0698
Dir. of Survey
Downstream
Length Surveyed
1605.6 ft.
Total Length
1605.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4211
O&M Rating
9
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole C 0699 to C 0698
MH: C 0699MH: C 0698downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 06990 ft. MGO - General Observation - HEAVY STEAM IN SEWER0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area930.5 ft. LR - Alignment Right, 10 %, Start1430.5 ft. LR - Alignment Right, 10 %, Finish1600.3 ft. LR - Alignment Right, 30 %1605.6 ft. MSA - Survey Abandoned - UNABLE TO PASS TURN IN PIPE

Observation photos (2)

  • Alignment Right, 10 %, Start

    930.5 ft. - Alignment Right, 10 %, Start

  • Alignment Right, 30 %

    1600.3 ft. - Alignment Right, 30 %

Observations (8)

DistanceCodeObservation
0AMHC 0699
1430.5LR
930.5LR
0MGOHEAVY STEAM IN SEWER
1600.3LR
1605.6MSAUNABLE TO PASS TURN IN PIPE
0MWM
0MWL

Properties (8)

custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-03-23T00:11:26-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FACTORY
year_laid
40310