- Date
- 05/06/2021
- W/O
- 891205
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00746
- PipeID
- P19353
- Time
- 3:17 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8902
- Sewer Name
- 20 5TH STREET EAST TRUNK
- City
- PALMDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 20
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_891205_TV20059_MAY2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 20 0404
- Downstream MH
- 20 0403
- Dir. of Survey
- Downstream
- Length Surveyed
- 301.1 ft.
- Total Length
- 301.1 ft.
- Structural Index
- 3
- Structural Quick
- 413J
- Structural Rating
- 163
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 118
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 281
Pipe schematic from manhole 20 0404 to 20 0403 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

6.9 ft. - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

31.7 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

39.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start