Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 12, 2021, 09:05 AM
  • J 0226_J 0225_5122021_021624.mp4

Date
05/12/2021
W/O
0880100
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11472
Time
2:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1803
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Capital Improvement Program Assesment
Project
20210511MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0226
Downstream MH
J 0225
Dir. of Survey
Downstream
Length Surveyed
425.7 ft.
Total Length
425.7 ft.
Structural Index
4
Structural Quick
5541
Structural Rating
35
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
39
Pipe schematic from manhole J 0226 to J 0225
MH: J 0226MH: J 0225downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. MGP - General Photograph - MISSING LONG & CIRCUM REBAR2 ft. MGO - General Observation - MAG COAT 40% START2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - NG & CIRCUM REBAR CORRODED & MISSING4.1 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR8.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - ROCKS12.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORROSION BEYOUND REBAR78.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - ROCKS84.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE94.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR217.9 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR230.8 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - ROCKS332.9 ft. SRC - Surface Reinforcement Corroded, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR389.2 ft. SSS - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE425.2 ft. MGO - General Observation - MAG COAT 40% FINISH425.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped425.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG425.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE425.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped425.7 ft. AMH - Downstream Manhole, Survey Ends - 3:05AM

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • General Photograph - MISSING LONG & CIRCUM REBAR

    2 ft. - General Photograph - MISSING LONG & CIRCUM REBAR

  • General Observation - MAG COAT 40% START

    2 ft. - General Observation - MAG COAT 40% START

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - NG & CIRCUM REBAR CORRODED & MISSING

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - NG & CIRCUM REBAR CORRODED & MISSING

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR

    4.1 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO - MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORROSION BEYOUND REBAR

    12.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORROSION BEYOUND REBAR

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    84.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    217.9 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    332.9 ft. - Surface Reinforcement Corroded, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    389.2 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

Observations (24)

DistanceCodeObservation
2SSSBLISTERING PEELING CONCRETE
2MGPMISSING LONG & CIRCUM REBAR
425.2MGOMAG COAT 40% FINISH
2MGOMAG COAT 40% START
84.4SSSBLISTERING CONCRETE
0MWM
332.9SRCCIRCUM REBAR
217.9SRCCIRCUM REBAR
425.2MGOConn. @ Mh, 9 O' Clock. Capped
425.7AMH3:05AM
425.2SAMSEVERE AGG
0AMH2:15AM
425.2SSSBLISTERING PEELING CONCRETE
4.1SRCMISSING REBAR
2SAMSEVERE AGG
2SRCNG & CIRCUM REBAR CORRODED & MISSING
389.2SSSPEELING CONCRETE
94.3SRCLONG & CIRCUM REBAR
78.2DSZROCKS
230.8DSZROCKS
0MWL
8.9DSZROCKS
12.9SRCCORROSION BEYOUND REBAR
425.2MGOConn. @ Mh, 3 O' Clock. Capped

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED & MISSING
custom_field_two
1
customer
LACSD
datetime
2021-05-12T02:05:24-07:00
documentation
MARTIN,OLIVER 111,RUVALCABA,BARR
is_lateral_inspection
false