- Date
- 05/11/2021
- W/O
- 0879983
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00057
- PipeID
- P11479
- Time
- 4:36 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1797
- Sewer Name
- J JOINT OUTFALL J - UNIT 1E
- City
- PALO VERDES
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 47
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210511MDM_JOINT_OUTFALL_J_UNIT_1E
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Upstream MH
- J 0232
- Downstream MH
- J 0233
- Dir. of Survey
- Upstream
- Length Surveyed
- 150.8 ft.
- Total Length
- 150.8 ft.
- Structural Index
- 4
- Structural Quick
- 5321
- Structural Rating
- 17
- O&M Index
- 2
- O&M Quick
- 3122
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 24
Pipe schematic from manhole J 0232 to J 0233 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

72.3 ft. - Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR

73.6 ft. - Surface Reinforcement Corroded, from 01 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

110.1 ft. - Surface Reinforcement Corroded, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR