Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 22, 2016, 07:08 AM
  • 05 0344_05 0343 _21112016_232309.mp4

Date
11/21/2016
W/O
602767
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05558
Time
11:08 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3832
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
WO_602767_TV05325_NOV2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
05 0344
Downstream MH
05 0343
Dir. of Survey
Downstream
Length Surveyed
495.6 ft.
Total Length
495.6 ft.
Structural Index
4
Structural Quick
5Q3S
Structural Rating
734
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
734
Pipe schematic from manhole 05 0344 to 05 0343
MH: 05 0344MH: 05 0343downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 03440 ft. MWM - Water Mark, 45 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start52 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start493 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish493.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish495.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0343

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    52 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
493.9SAV
0MWL
0AMH05 0344
495.6AMH05 0343
0MWM
2.1SAV
52SRV
493SRV

Properties (6)

additional_info
SC304581
custom_field_two
2
customer
LACSD
datetime
2016-11-21T23:08:10-08:00
documentation
PROPIPE
is_lateral_inspection
false