Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 2, 2016, 07:35 AM
  • 02 0112_02 0112_110216_005949.mp4

Date
11/02/2016
W/O
602602
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00237
PipeID
P02279
Time
12:35 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3754
Sewer Name
02 BELLFLOWER TRUNK
City
BELLFLOWER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
WO_602602_TV02019_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
02 0111
Downstream MH
02 0112
Dir. of Survey
Upstream
Length Surveyed
313.4 ft.
Total Length
313.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 0111 to 02 0112
MH: 02 0111MH: 02 0112upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 011255.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"64.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"72 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"83 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ DEBRIS97.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - W/ DEBRIS109.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"133 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"159.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ DEBRIS183 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ FRACTURE210 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"233.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"236 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"257 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"283.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"311.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES313.4 ft. MWM - Water Mark, 15 %of cross sectional area313.4 ft. AMH - Downstream Manhole, Survey Begins - 02 0111313.4 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ FRACTURE

    130.4 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4" - W/ FRACTURE

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - W/ DEBRIS

    215.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - W/ DEBRIS

Observations (19)

DistanceCodeObservation
180.4TF
0MWM
204.3TFA
0AMH02 0111
257.5TF
313.4AMH02 0112
56.4TFA
79.7TF
130.4TFAW/ FRACTURE
215.9TFW/ DEBRIS
241.4TFA
249.1TB
0MWL
77.4TF
29.9TFA
153.9TFW/ DEBRIS
230.4TFW/ DEBRIS
2CM
103.4TF

Properties (6)

additional_info
SC303746
custom_field_two
4
customer
LACSD
datetime
2016-11-02T00:35:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false