Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2016, 11:20 AM
  • 02 1636_02 1635_08112016_032413.mp4

Date
11/08/2016
W/O
602593
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00235
PipeID
P04073
Time
3:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3819
Sewer Name
02 ATLANTIC AVENUE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_602593_TV02018_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1636
Downstream MH
02 1635
Dir. of Survey
Downstream
Length Surveyed
111.3 ft.
Total Length
111.3 ft.
Structural Index
3
Structural Quick
3C21
Structural Rating
62
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
62
Pipe schematic from manhole 02 1636 to 02 1635
MH: 02 1636MH: 02 1635downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 16360 ft. MWL - Water Level, 5 %of cross sectional area6.2 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES8.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start108.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish111.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK111.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1635

Observation photos (2)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    6.2 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
0AMH02 1636
0MWL
111.3MGOCONNECTION AT MH 9 O'CLOCK
108.1CM
8.8CM
6.2CL
111.3AMH02 1635

Properties (6)

additional_info
SC304568
custom_field_two
3
customer
LACSD
datetime
2016-11-08T03:20:20-08:00
documentation
PROPIPE
is_lateral_inspection
false