Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 14, 2016, 10:39 AM
  • 02 1807_02 1806_14112016_024025.mp4

Date
11/14/2016
W/O
602593
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00236
PipeID
P04154
Time
2:39 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3822
Sewer Name
02 ATLANTIC AVENUE RELIEF TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_602593_TV02018_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1807
Downstream MH
02 1806
Dir. of Survey
Downstream
Length Surveyed
251.2 ft.
Total Length
251.2 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 02 1807 to 02 1806
MH: 02 1807MH: 02 1806downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 18070 ft. MWM - Water Mark, 15 %of cross sectional area82.6 ft. CM - Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES178.8 ft. CM - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES186.8 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES210 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES251.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1806

Observation photos (4)

  • Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES

    82.6 ft. - Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

    178.8 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    186.8 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    210 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
186.8CL
210CM
82.6CM
178.8CM
251.2AMH02 1806
0MWL
0AMH02 1807
0MWM

Properties (6)

additional_info
SC304571
custom_field_two
4
customer
LACSD
datetime
2016-11-14T02:39:46-08:00
documentation
PROPIPE
is_lateral_inspection
false