Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 10, 2016, 08:59 AM
  • 02 1625_02 1624_10112016_005944.mp4

Date
11/10/2016
W/O
602593
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00235
PipeID
P04062
Time
12:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3821
Sewer Name
02 ATLANTIC AVENUE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_602593_TV02018_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1624
Downstream MH
02 1625
Dir. of Survey
Upstream
Length Surveyed
259.5 ft.
Total Length
259.5 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
135
Pipe schematic from manhole 02 1624 to 02 1625
MH: 02 1624MH: 02 1625upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 02 162515.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"60.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"97.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"112.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"171 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start226.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"259.5 ft. MWL - Water Level, 10 %of cross sectional area259.5 ft. AMH - Downstream Manhole, Survey Begins - 02 1624259.5 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    37 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
146.6TF
259.5CM
198.6TF
37CM
259.5AMH02 1625
32.9TF
0MWL
243.7TF
0AMH02 1624
161.7TF
88.5TF
0MWM

Properties (6)

additional_info
SC304570
custom_field_two
3
customer
LACSD
datetime
2016-11-10T00:59:06-08:00
documentation
PROPIPE
is_lateral_inspection
false