- Date
- 11/08/2016
- W/O
- 602593
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00235
- PipeID
- P04080
- Time
- 11:32 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3820
- Sewer Name
- 02 ATLANTIC AVENUE TRUNK
- City
- EAST LOS ANGELES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_602593_TV02018_NOV2016
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 02 1646
- Downstream MH
- 02 1645
- Dir. of Survey
- Downstream
- Length Surveyed
- 301.4 ft.
- Total Length
- 301.4 ft.
- Structural Index
- 3
- Structural Quick
- 413J
- Structural Rating
- 177
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 177
Pipe schematic from manhole 02 1646 to 02 1645 Observation photos (4)

11.1 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

14 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

136.3 ft. - Fracture Multiple, from 06 to 05 o'clock, within 8 inches of joint: YES

171.8 ft. - Fracture Circumferential, from 06 to 10 o'clock, within 8 inches of joint: YES