Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2016, 06:11 AM
  • 02 1649_02 1648_08112016_223837.mp4

Date
11/08/2016
W/O
602593
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00235
PipeID
P04083
Time
10:11 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3820
Sewer Name
02 ATLANTIC AVENUE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
WO_602593_TV02018_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
02 1648
Downstream MH
02 1649
Dir. of Survey
Upstream
Length Surveyed
463.5 ft.
Total Length
463.5 ft.
Structural Index
3
Structural Quick
3H22
Structural Rating
136
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
136
Pipe schematic from manhole 02 1648 to 02 1649
MH: 02 1648MH: 02 1649upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 16496.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES23.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"71.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"83 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"155.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"167.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"206.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"236.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish270.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"303 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"309.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"327.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"367 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"406.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"453.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start456.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES459.9 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES463.5 ft. MWL - Water Level, 5 %of cross sectional area463.5 ft. AMH - Downstream Manhole, Survey Begins - 02 1648463.5 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (5)

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    6.7 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    440.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    457.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
463.5AMH02 1649
0MWL
440.3TB
154.1TFC
57.3TF
256.9TF
3.6CM
296TF
0AMH02 1648
96.5TF
457.4CL
307.9TF
193.1TF
0MWM
392.2TF
160.5TB
227.2CM
10CM
380.5TF
6.7CL
136.4TF

Properties (6)

additional_info
SC304569
custom_field_two
3
customer
LACSD
datetime
2016-11-08T22:11:25-08:00
documentation
PROPIPE
is_lateral_inspection
false