Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 12, 2016, 11:02 AM
  • H 0621H 0620_02121643_030236.mp4

Date
02/12/2016
W/O
552365
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00191
PipeID
P11040
Time
3:02 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3145
Sewer Name
H JOINT OUTFALL H - UNIT 8H
City
WEST COVINA, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_552365_TV15175_FEB2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
H 0621
Downstream MH
H 0620
Dir. of Survey
Downstream
Length Surveyed
464.4 ft.
Total Length
464.4 ft.
Structural Index
1
Structural Quick
1Q00
Structural Rating
90
O&M Index
2
O&M Quick
412Q
O&M Rating
186
Overall Index
2
Overall Quick
Overall Rating
276
Pipe schematic from manhole H 0621 to H 0620
MH: H 0621MH: H 0620downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 06212 ft. MGO - General Observation - MAGNESIUM H.O. START7.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.5 ft. SRI - Surface Roughness Increased, from 09 to 03 o'clock, within 8 inches of joint: YES, Start36.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"84.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"191 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"288 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4"343 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"366.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"392.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"416.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"459.9 ft. SRI - Surface Roughness Increased, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish459.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish464.4 ft. AMH - Downstream Manhole, Survey Ends - H 0620

Observation photos (5)

  • General Observation - MAGNESIUM H.O. START

    2 ft. - General Observation - MAGNESIUM H.O. START

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    7.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    36.1 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    84.3 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"

  • Surface Roughness Increased, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

    459.9 ft. - Surface Roughness Increased, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observations (17)

DistanceCodeObservation
36.1TFC
84.3TFC
288TFC
0MWM
392.3TFC
459.9SRI
7.5SRI
0MWL
7.3DAGS
0AMHH 0621
459.9DAGS
416.7TFC
366.3TFC
464.4AMHH 0620
2MGOMAGNESIUM H.O. START
191TFC
343TFC

Properties (6)

additional_info
SC225532
custom_field_two
4
customer
LACSD
datetime
2016-02-12T03:02:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false