Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 25, 2016, 11:56 AM
  • 21 0950_21 0949_20160225_051100.mp4

Date
02/25/2016
W/O
552362
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00760
PipeID
P16044
Time
3:56 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3207
Sewer Name
21 CLAREMONT OUTFALL TRUNK
City
CLAREMONT, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
07
Purpose
Routine Assessment
Project
WO_552362_TV210004_FEB2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
21 0949
Downstream MH
21 0950
Dir. of Survey
Upstream
Length Surveyed
586.5 ft.
Total Length
586.5 ft.
Structural Index
3
Structural Quick
3V00
Structural Rating
348
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
348
Pipe schematic from manhole 21 0949 to 21 0950
MH: 21 0949MH: 21 0950upstream0 ft. AMH - Upstream Manhole, Survey Ends - 21 09502.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish123.1 ft. RPR - Repair Pipe Replaced, within 8 inches of joint: YES - VCP179.9 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"352.4 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 4"417.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"505.7 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"560.9 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 4"584.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start586.5 ft. MWM - Water Mark, 20 %of cross sectional area586.5 ft. MWL - Water Level, 5 %of cross sectional area586.5 ft. AMH - Downstream Manhole, Survey Begins - 21 0949

Observation photos (3)

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    80.8 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"

    406.6 ft. - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"

  • Repair Pipe Replaced, within 8 inches of joint: YES - VCP

    463.4 ft. - Repair Pipe Replaced, within 8 inches of joint: YES - VCP

Observations (12)

DistanceCodeObservation
0MWM
0MWL
463.4RPRVCP
2SAV
406.6TBA
234.1TBA
584SAV
586.5AMH21 0950
80.8TBA
169.1TFC
25.6TBA
0AMH21 0949

Properties (6)

additional_info
SC225545
custom_field_two
3
customer
LACSD
datetime
2016-02-25T03:56:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false