Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 24, 2016, 07:53 AM
  • 04 0079_04 0078A_23022016_235417.mp4

Date
02/23/2016
W/O
552531
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11817
Time
11:53 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3265
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Routine Assessment
Project
WO_552531_TV04009_FEB2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Lining Method
Segmented Panel
Shape
Circular
Height
15 in.
Upstream MH
04 0079
Downstream MH
04 0078A
Dir. of Survey
Downstream
Length Surveyed
321.3 ft.
Total Length
321.3 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
18
O&M Index
2
O&M Quick
322M
O&M Rating
151
Overall Index
2
Overall Quick
Overall Rating
169
Pipe schematic from manhole 04 0079 to 04 0078A
MH: 04 0079MH: 04 0078Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 04 00792 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start35 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES37.4 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS37.4 ft. RML - Roots Medium Lateral, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES39.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.9 ft. RML - Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES82.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS85.8 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS105.3 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES124.1 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS124.1 ft. RFL - Roots Fine Lateral, from 01 to 04 o'clock134.9 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS140 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"174.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start178.2 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS182.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start193.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"205.4 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish216.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"259 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"271.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"317.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"319.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish319.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"319.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish319.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish321.3 ft. AMH - Downstream Manhole, Survey Ends - 04 0078A321.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK321.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (17)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    8.9 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    35 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    37.4 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Medium Lateral, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES

    37.4 ft. - Roots Medium Lateral, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES

  • Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES

    82.9 ft. - Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    82.9 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    85.8 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    105.3 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    124.1 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Fine Lateral, from 01 to 04 o'clock

    124.1 ft. - Roots Fine Lateral, from 01 to 04 o'clock

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    134.9 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    174.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    178.2 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    182.6 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    321.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (35)

DistanceCodeObservation
37.4TFDROOTS
0MWL
35CL
216.8TFA
0MWM
319.6CM
321.3AMH04 0078A
319.6TFA
2DAGS
0MGOCOCKROACHES IN MANHOLE
85.8TFDROOTS
105.3CL
205.4FM
82.9RML
0AMH04 0079
259TFA
321.3MGOACTIVE CONNECTION AT MH 9 O'CLOCK
271.2TFC
140TFA
178.2TFDROOTS
124.1TFDROOTS
39.1TFA
317.6TFC
319.6DAE
134.9TFDROOTS
193.7TF
37.4RML
321.3MGOCOCKROACHES IN MANHOLE
82.9TFDROOTS
319.6DAGS
8.9DAE
174.3CM
224.6TBA
182.6FM
124.1RFL

Properties (6)

additional_info
SC225488
custom_field_two
2
customer
LACSD
datetime
2016-02-23T23:53:11-08:00
documentation
PRO PIPE
is_lateral_inspection
false