Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2015, 12:51 PM
  • 08 0500A_08 0500_20151207_050151.mp4

Date
12/07/2015
W/O
531054
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00021
PipeID
P00560
Time
4:51 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2925
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0500A
Downstream MH
08 0500
Dir. of Survey
Downstream
Length Surveyed
95.1 ft.
Total Length
95.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0500A to 08 0500
MH: 08 0500AMH: 08 0500downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 0500A0 ft. MWM - Water Mark, 35 %of cross sectional area12.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"58.8 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES65 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"95.1 ft. VC - Vermin Cockroach95.1 ft. AMH - Downstream Manhole, Survey Ends - 08 050095.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 O' CLOCK

Observations (9)

DistanceCodeObservation
95.1VC
0MWL
12.1TFC
95.1AMH08 0500
0AMH08 0500A
65TFC
58.8CM
0MWM
95.1MGOCONNECTION AT THE MH 3 O' CLOCK

Properties (6)

additional_info
SC207026
custom_field_two
4
customer
LACSD
datetime
2015-12-07T04:51:26-08:00
documentation
PRO-PIPE
is_lateral_inspection
false