Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2015, 11:30 AM
  • 08 0505_08 0504_20151103_034143.mp4

Date
11/03/2015
W/O
531054
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00021
PipeID
P00564
Time
3:30 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2545
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0505
Downstream MH
08 0504
Dir. of Survey
Downstream
Length Surveyed
149.9 ft.
Total Length
149.9 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 08 0505 to 08 0504
MH: 08 0505MH: 08 0504downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 0505 (0330)3 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS4.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"7.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"95 ft. MLC - Lining Change, Cured in place101.1 ft. LFD - Lining Failure Detached, from 11 to 01 o'clock, within 8 inches of joint: NO104.9 ft. MMC - Material Change, Vitrified clay pipe106.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start124.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish146.9 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - DEBRIS149.9 ft. MGO - General Observation - CONNECTIONS CAPPED 3 AND 9 O;CLOCK149.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0504

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    120.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
104.9MMC
3DSZDEBRIS
106.2TFC
7.4TFC
146.9DSZDEBRIS
4.6TFC
0MWM
101.1LFD
0MWL
0AMH08 0505 (0330)
149.9MGOCONNECTIONS CAPPED 3 AND 9 O;CLOCK
120.6FM
95MLC
149.9AMH08 0504
124.9FM

Properties (6)

additional_info
SC205609
custom_field_two
3
customer
LACSD
datetime
2015-11-03T03:30:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false