Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2015, 11:35 AM
  • 08 0506_08 0590_20151207_034457.mp4

Date
12/07/2015
W/O
531054
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00021
PipeID
P00567
Time
3:35 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2925
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0506
Downstream MH
08 0590
Dir. of Survey
Downstream
Length Surveyed
125.5 ft.
Total Length
125.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4131
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 08 0506 to 08 0590
MH: 08 0506MH: 08 0590downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 5 O' CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 08 05060 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 20 %of cross sectional area41.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"60.4 ft. RMJ - Roots Medium Joint, from 09 to 11 o'clock, 10 %, within 8 inches of joint: YESR94.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"125.5 ft. AMH - Downstream Manhole, Survey Ends - 08 0590

Observations (9)

DistanceCodeObservation
94.1TFC
60.4RMJ
0MGOCONNECTION AT THE MH 5 O' CLOCK
125.5AMH08 0590
0AMH08 0506
41.9TFC
0MWM
0VC
0MWL

Properties (6)

additional_info
SC207026
custom_field_two
4
customer
LACSD
datetime
2015-12-07T03:35:44-08:00
documentation
PRO-PIPE
is_lateral_inspection
false