Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2015, 11:05 AM
  • 08 0508_08 0507_20151103_031335.mp4

Date
11/03/2015
W/O
531054
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00021
PipeID
P00569
Time
3:05 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2545
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0508
Downstream MH
08 0507
Dir. of Survey
Downstream
Length Surveyed
222.4 ft.
Total Length
222.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole 08 0508 to 08 0507
MH: 08 0508MH: 08 0507downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 0508 (0305)0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area39.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"144.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"181.4 ft. MWM - Water Mark, 80 %of cross sectional area222.4 ft. MGO - General Observation - LATERAL AT MH 12 0CLOCK222.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0507 (0309)

Observations (8)

DistanceCodeObservation
0AMH08 0508 (0305)
222.4MGOLATERAL AT MH 12 0CLOCK
0MWM
222.4AMH08 0507 (0309)
181.4MWM
144.1TFC
0MWL
39.3TFC

Properties (6)

additional_info
SC205609
custom_field_two
4
customer
LACSD
datetime
2015-11-03T03:05:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false