Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 1, 2015, 09:28 AM
  • 08 0520A_08 0520_20151201_015117.mp4

Date
12/01/2015
W/O
531054
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00021
PipeID
P00583
Time
1:28 AM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2920
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0520A
Downstream MH
08 0520
Dir. of Survey
Downstream
Length Surveyed
38.4 ft.
Total Length
38.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
4127
O&M Rating
18
Overall Index
2
Overall Quick
Overall Rating
21
Pipe schematic from manhole 08 0520A to 08 0520
MH: 08 0520AMH: 08 0520downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 0520A0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 O' CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start32.2 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO35.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish38.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0520

Observation photos (1)

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO

    32.2 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO

Observations (8)

DistanceCodeObservation
2DAGS
38.4AMH08 0520
0AMH08 0520A
32.2CM
0MWL
35.6DAGS
0MWM
0MGOCONNECTION AT THE MH 3 O' CLOCK

Properties (6)

additional_info
SC207018
custom_field_two
3
customer
LACSD
datetime
2015-12-01T01:28:38-08:00
documentation
PRO-PIPE
is_lateral_inspection
false