- Date
- 12/01/2015
- W/O
- 531054
- Weather
- Dry
- Operator/Surveyor
- N.ZAHREDDINE
- Sewer ID
- Z00021
- PipeID
- P00586
- Time
- 3:59 AM
- Certificate
- U-109-7948
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K2920
- Sewer Name
- 08 VICTORIA STREET TRUNK
- City
- CARSON, CA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- WO_531054_TV08032_OCT2015
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 08 0523
- Downstream MH
- 08 0524
- Dir. of Survey
- Upstream
- Length Surveyed
- 253.5 ft.
- Total Length
- 253.5 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 312I
- O&M Rating
- 111
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 111
Pipe schematic from manhole 08 0523 to 08 0524 Observation photos (4)

33.1 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

148.2 ft. - Roots Medium Joint, from 02 to 05 o'clock, 15 %, within 8 inches of joint: YESR

154.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

156.8 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR, Start