Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2015, 07:15 AM
  • 08 0535_08 0534_20151103_233025.mp4

Date
11/03/2015
W/O
531054
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00021
PipeID
P00597
Time
11:15 PM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2546
Sewer Name
08 VICTORIA STREET TRUNK
City
CARSON, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_531054_TV08032_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0535
Downstream MH
08 0534
Dir. of Survey
Downstream
Length Surveyed
244.4 ft.
Total Length
244.4 ft.
Structural Index
4
Structural Quick
4231
Structural Rating
11
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 08 0535 to 08 0534
MH: 08 0535MH: 08 0534downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 0535 (23160 ft. MGO - General Observation - LATERAL AT MH 3 0CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start114.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES125.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES148.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start244.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish244.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish244.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0534 (2330)

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    114.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    125.8 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
244.4CM
244.4DAGS
0AMH08 0535 (2316
244.4AMH08 0534 (2330)
2.1DAGS
0MGOLATERAL AT MH 3 0CLOCK
114.1FM
0MWM
0MGOLATERAL AT MH 9 OCLOCK
148.6CM
0MWL
125.8FM

Properties (6)

additional_info
SC205610
custom_field_two
2
customer
LACSD
datetime
2015-11-03T23:15:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false