Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2015, 09:11 AM
  • 14 0181_14 0180_20151113_012329.mp4

Date
11/13/2015
W/O
525225
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00584
PipeID
P18220
Time
1:11 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2829
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
08
Purpose
Routine Assessment
Project
WO_525225_TV14034_SEPT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
14 0181
Downstream MH
14 0180
Dir. of Survey
Downstream
Length Surveyed
302.3 ft.
Total Length
302.3 ft.
Structural Index
3
Structural Quick
4135
Structural Rating
19
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole 14 0181 to 14 0180
MH: 14 0181MH: 14 0180downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 01812 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start102 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES190.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES194.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES202.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES206.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start223.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"273.7 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"299.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish299.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish302.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0180

Observation photos (2)

  • Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

    102 ft. - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    194.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
223.5TFC
0MWL
0MWM
302.3AMH14 0180
299.5DAGS
202.5CM
273.7TFC
299.5CM
2DAGS
194.3FM
0AMH14 0181
206.4CM
102CM
190.3CM

Properties (7)

additional_info
SC204163
custom_field_two
3
customer
LACSD
datetime
2015-11-13T01:11:35-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
20011130