Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2015, 07:44 AM
  • 14 0186_14 0185_20151112_235910.mp4

Date
11/12/2015
W/O
525225
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00584
PipeID
P18225
Time
11:44 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2829
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
08
Purpose
Routine Assessment
Project
WO_525225_TV14034_SEPT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
14 0186
Downstream MH
14 0185
Dir. of Survey
Downstream
Length Surveyed
302 ft.
Total Length
302 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2K00
O&M Rating
120
Overall Index
2
Overall Quick
Overall Rating
126
Pipe schematic from manhole 14 0186 to 14 0185
MH: 14 0186MH: 14 0185downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 01860 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start41.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"90 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"141.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"142 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES188.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"238.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES239.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"287.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"300.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish302 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK302 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 12 O'CLOCK302 ft. AMH - Downstream Manhole, Survey Ends - 14 0185

Observations (16)

DistanceCodeObservation
90TFC
142CM
287.5TFC
238.2CM
0MWM
188.4TFC
302MGOACTIVE CONNECTION AT MH 3 O'CLOCK
2DAGS
300.8DAGS
239.6TFC
0AMH14 0186
0MWL
302MGOACTIVE CONNECTION AT MH 12 O'CLOCK
141.6TFC
41.3TFC
302AMH14 0185

Properties (6)

additional_info
SC204163
custom_field_two
3
customer
LACSD
datetime
2015-11-12T23:44:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false