Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2015, 07:30 AM
  • 14 0187_14 0186_20151112_234417.mp4

Date
11/12/2015
W/O
525225
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00584
PipeID
P18226
Time
11:30 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2829
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
08
Purpose
Routine Assessment
Project
WO_525225_TV14034_SEPT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
14 0187
Downstream MH
14 0186
Dir. of Survey
Downstream
Length Surveyed
328.3 ft.
Total Length
328.3 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
136
Pipe schematic from manhole 14 0187 to 14 0186
MH: 14 0187MH: 14 0186downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 01870 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start11 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"62.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"113.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"174.4 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES213 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"264.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"311.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"313.7 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES325.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish328.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0186

Observations (15)

DistanceCodeObservation
161.3TFA
328.3AMH14 0186
325.7DAGS
11TFC
213TFC
62.3TFC
0MWM
2DAGS
0AMH14 0187
0MWL
313.7CM
113.7TFC
264.7TFC
311.8TFC
174.4CM

Properties (6)

additional_info
SC204163
custom_field_two
3
customer
LACSD
datetime
2015-11-12T23:30:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false