Wastewater/Activity/PacpInspection/1.0Sep 22, 2017, 06:28 AM
  • 29 0817_29 0287 _21092017_233740.mp4

Date
09/21/2017
W/O
658119
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00375
PipeID
P24198
Time
11:28 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4887
Sewer Name
29 ORANGE AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
WO_658119_TV29040_SEP2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0817
Downstream MH
29 0287
Dir. of Survey
Downstream
Length Surveyed
176.3 ft.
Total Length
176.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 29 0817 to 29 0287
MH: 29 0817MH: 29 0287downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 08170 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 5 %of cross sectional area2.9 ft. CM - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES20.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"63.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"65 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN96.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"124.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"162.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"175 ft. MGO - General Observation - SPALLING THROUGHOUT THE REACH176.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK176.3 ft. AMH - Downstream Manhole, Survey Ends - 29 0287

Observation photos (1)

  • Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

    2.9 ft. - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
175MGOSPALLING THROUGHOUT THE REACH
0AMH29 0817
96.7TF
162.2TF
176.3MGOCONNECTION AT MH 3 O'CLOCK
0MWL
63.7TF
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
2.9CM
20.5TF
65TFDBROKEN
124.5TF
176.3AMH29 0287

Properties (7)

additional_info
SC345947
custom_field_two
3
customer
LACSD
datetime
2017-09-21T23:28:39-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
39295