- Date
- 04/29/2021
- W/O
- 885818
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00106
- PipeID
- P09286
- Time
- 1:52 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8794
- Sewer Name
- B JOINT OUTFALL B - UNIT 8C
- City
- TEMPLE CITY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- RFIR_WO_885818_TV15228_APR2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 21 in.
- Upstream MH
- B 0621
- Downstream MH
- B 0620
- Dir. of Survey
- Downstream
- Length Surveyed
- 400.4 ft.
- Total Length
- 400.4 ft.
- Structural Index
- 3
- Structural Quick
- 3O2O
- Structural Rating
- 390
- O&M Index
- 2
- O&M Quick
- 2O00
- O&M Rating
- 158
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 548
Pipe schematic from manhole B 0621 to B 0620 Observation photos (5)

2 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

5.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

400.4 ft. - General Observation - COCKROACHES IN MANHOLE