- Date
- 04/01/2021
- W/O
- 886227
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00539
- PipeID
- P06873
- Time
- 10:15 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8720
- Sewer Name
- 05 WEST TORRANCE TRUNK
- City
- TORRANCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- WO_886227_TV05132_APR2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 05 1650
- Downstream MH
- 05 1649
- Dir. of Survey
- Downstream
- Length Surveyed
- 404.3 ft.
- Total Length
- 404.3 ft.
- Structural Index
- 3
- Structural Quick
- 3O2O
- Structural Rating
- 400
- O&M Index
- 2
- O&M Quick
- 2O00
- O&M Rating
- 160
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 560
Pipe schematic from manhole 05 1650 to 05 1649 Observation photos (4)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

65.3 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

172.1 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"

328.7 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"