Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 1, 2021, 08:51 AM
  • 05 1667_05 1666_04012021_020252.mp4

Date
04/01/2021
W/O
886227
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06891
Time
1:51 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8719
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
WO_886227_TV05132_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
12 in.
Upstream MH
05 1666
Downstream MH
05 1667
Dir. of Survey
Upstream
Length Surveyed
272.6 ft.
Total Length
272.6 ft.
Structural Index
3
Structural Quick
3J2J
Structural Rating
270
O&M Index
2
O&M Quick
412J
O&M Rating
112
Overall Index
2
Overall Quick
Overall Rating
382
Pipe schematic from manhole 05 1666 to 05 1667
MH: 05 1666MH: 05 1667upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 16670 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish48.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN92.1 ft. RBC - Roots Ball Connection, at 12 o'clock, 85 %92.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN147.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN195.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN242.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN252.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN270.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start270.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start270.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start272.6 ft. AMH - Downstream Manhole, Survey Begins - 05 1666272.6 ft. MWM - Water Mark, 30 %of cross sectional area272.6 ft. MGO - General Observation - CONN @ MH 1 O'CLOCK/ACTIVE272.6 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    20.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Roots Ball Connection, at 12 o'clock, 85 %

    180.5 ft. - Roots Ball Connection, at 12 o'clock, 85 %

Observations (18)

DistanceCodeObservation
180.5RBC
0AMH05 1666
270DAGS
2SSS
180.5TFUNKNOWN
77.3TFOPEN
30TFOPEN
272.6AMH05 1667
124.8TFOPEN
0MWM
224.1TFOPEN
20.1TBOPEN
0MGOCONN @ MH 1 O'CLOCK/ACTIVE
270SSS
0MWL
272.6CM
2DAGS
2CM

Properties (7)

additional_info
630074033121204
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-04-01T01:51:46-07:00
documentation
PROPIPE
is_lateral_inspection
false