Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2021, 08:43 AM
  • 05 1659A_05 1659_04192021_014729.mp4

Date
04/19/2021
W/O
886227
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06883
Time
1:43 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8733
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
WO_886227_TV05132_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
12 in.
Upstream MH
05 1659A
Downstream MH
05 1659
Dir. of Survey
Downstream
Length Surveyed
75.8 ft.
Total Length
75.8 ft.
Structural Index
3
Structural Quick
3B2B
Structural Rating
73
O&M Index
2
O&M Quick
2B00
O&M Rating
28
Overall Index
2
Overall Quick
Overall Rating
101
Pipe schematic from manhole 05 1659A to 05 1659
MH: 05 1659AMH: 05 1659downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 1659A0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"64.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN73 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish73 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish75.8 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE75.8 ft. AMH - Downstream Manhole, Survey Ends - 05 165975.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
2DAGS
18TFC
2SSS
0MWM
0AMH05 1659A
2CM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
64.2TFOPEN
75.8MGOCONN @ MH 9 O'CLOCK/ACTIVE
75.8AMH05 1659
73DAGS
75.8CM
73SSS
0MWL

Properties (7)

additional_info
630074041921001
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-04-19T01:43:10-07:00
documentation
PROPIPE
is_lateral_inspection
false