Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 2, 2021, 09:27 AM
  • 05 1654_05 1653_04022021_023907.mp4

Date
04/02/2021
W/O
886227
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06877
Time
2:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8720
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
30
Purpose
Routine Assessment
Project
WO_886227_TV05132_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1653
Downstream MH
05 1654
Dir. of Survey
Upstream
Length Surveyed
301.3 ft.
Total Length
301.3 ft.
Structural Index
2
Structural Quick
3J2K
Structural Rating
286
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
288
Pipe schematic from manhole 05 1653 to 05 1654
MH: 05 1653MH: 05 1654upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 16542.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish4.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish40.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"141.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"189.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"236.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"288.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - open299.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start299.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start299.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES301.3 ft. MWL - Water Level, 25 %of cross sectional area301.3 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/OPEN301.3 ft. AMH - Downstream Manhole, Survey Begins - 05 1653301.3 ft. MWM - Water Mark, 30 %of cross sectional area301.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
260.8TFC
64.5TFC
299SSS
13TFopen
0MWL
2SSS
0MGOCONN @ MH 9 O'CLOCK/OPEN
2CM
2DAGS
111.9TFC
0AMH05 1653
160.1TFC
297CM
0MWM
301.3AMH05 1654
0MGOCONN @ MH 3 O'CLOCK/CAPPED

Properties (7)

additional_info
630074040121201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-04-02T02:27:51-07:00
documentation
PROPIPE
is_lateral_inspection
false