Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 22, 2021, 09:56 AM
  • 15 0334_15 0333_04222021_025925.mp4

Date
04/22/2021
W/O
886343
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00598
PipeID
P12260
Time
2:56 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8787
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_886343_TV15016_APR2021
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
15 0334
Downstream MH
15 0333
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 15 0334 to 15 0333
MH: 15 0334MH: 15 0333downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 0334 EAST SIPHON0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES2 ft. MSA - Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

    2 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

Observations (5)

DistanceCodeObservation
0AMH15 0334 EAST SIPHON
0MWM
0MWL
2DAGS
2MSAVIEW OF DOWNLEG OF U/S EAST SIPHON.

Properties (7)

additional_info
630069042121203
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2021-04-22T02:56:05-07:00
documentation
PRO PIPE
is_lateral_inspection
false