- Date
- 05/04/2021
- W/O
- 0886345
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00878
- PipeID
- P17765
- Time
- 2:15 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1796
- Sewer Name
- 30 SOUTH BAY CITIES MAIN TRUNK
- City
- REDONDO BEACH
- Loc. details
- Alley
- Location Code
- H
- Use of Sewer
- Sanitary Sewer
- District
- District 30
- Page No.
- 05
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210504MDM_SOUTH_BAY_CITIED_MAIN_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 30 0062
- Downstream MH
- 30 0061
- Dir. of Survey
- Downstream
- Length Surveyed
- 388.9 ft.
- Total Length
- 388.9 ft.
- Structural Index
- 4
- Structural Quick
- 4321
- Structural Rating
- 14
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 30 0062 to 30 0061 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT

2 ft. - General Observation - 99% MAG COAT START

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDER MAG COAT

18.3 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

246.4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG