Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 24, 2021, 10:37 AM
  • 02 0642A_02 0642_03242021_035521.mp4

Date
03/24/2021
W/O
886194
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00258
PipeID
P03195
Time
3:37 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8667
Sewer Name
02 EAST COMPTON BOULEVARD EXTENSION TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
30
Purpose
Routine Assessment
Project
RFIR_WO_886194_TV02384_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 0642A
Downstream MH
02 0642
Dir. of Survey
Downstream
Length Surveyed
234.6 ft.
Total Length
234.6 ft.
Structural Index
3
Structural Quick
4D3H
Structural Rating
322
O&M Index
2
O&M Quick
2I00
O&M Rating
98
Overall Index
3
Overall Quick
Overall Rating
420
Pipe schematic from manhole 02 0642A to 02 0642
MH: 02 0642AMH: 02 0642downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0642A0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.1 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES19.1 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"22.5 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"42 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES72.4 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"75.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - OPEN94.4 ft. FM - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES121.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"206.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"232 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish234.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0642

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    17.1 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    42 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

    94.4 ft. - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
0MWL
121.9TFC
201.6TFC
232.3CM
0AMH02 0642A
206.4TFC
22.5TBC
42FM
2CM
234.6AMH02 0642
17.1FM
2DAGS
232SSS
19.1TBC
123.8TFC
75.7TBOPEN
2SSS
232.3DAGS
94.4FM
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
72.4TBC

Properties (7)

additional_info
630138032321202
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-24T03:37:25-07:00
documentation
PROPIPE
is_lateral_inspection
false