- Date
- 03/24/2021
- W/O
- 886194
- Weather
- Dry
- Operator/Surveyor
- J, BUENROSTRO
- Sewer ID
- Z00258
- PipeID
- P03188
- Time
- 11:44 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8668
- Sewer Name
- 02 EAST COMPTON BOULEVARD EXTENSION TRUNK
- City
- DOWNEY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- RFIR_WO_886194_TV02384_APR2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 18 in.
- Upstream MH
- 02 0636
- Downstream MH
- 02 0635
- Dir. of Survey
- Downstream
- Length Surveyed
- 219.3 ft.
- Total Length
- 219.3 ft.
- Structural Index
- 3
- Structural Quick
- 433H
- Structural Rating
- 230
- O&M Index
- 2
- O&M Quick
- 2H00
- O&M Rating
- 94
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 324
Pipe schematic from manhole 02 0636 to 02 0635 Observation photos (6)

2.4 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

6.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

39.4 ft. - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

59.6 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

197 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

213.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES