D 0142 D 0141 12092015 Manual.mp4
0 ft. - General Observation - MISSING TILES 100% 9:00 TO 3:00 START
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM & LONG REBAR
2 ft. - General Photograph - LONG REBAR
21.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - POSSILE MISSING REBAR
27.3 ft. - Surface Reinforcement Corroded, at 10 o'clock, within 8 inches of joint: NO - LONG REBAR
34.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - POSSIBLE MISSING REBAR
42.8 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - BROKEN REBAR
104.3 ft. - General Observation - MISSING TILES 30%
129.6 ft. - General Observation - MISSING TILES 20%
148.9 ft. - General Observation - MISSING TILES 50%
196 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - MISSING REBAR
199.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - MISSING & BROKEN REBAR
214.4 ft. - General Observation - MISSING TILES 70%
219.7 ft. - Surface Reinforcement Corroded, from 09 to 02 o'clock, within 8 inches of joint: YES
232.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES
238.8 ft. - General Observation - MISSING TILES 70%
252.1 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - BROKEN MISSING REBAR
282.9 ft. - General Observation - MISSING TILES 30%
290.6 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO
303.8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CORRODED BROKEN MISSING
341 ft. - General Observation - MISSING TILES 30%
439.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
445.2 ft. - General Observation - MISSING TILES 10%
462.2 ft. - General Observation - MISSING TILES 30%
498.2 ft. - Surface Reinforcement Corroded, from 09 to 02 o'clock, within 8 inches of joint: YES
516.8 ft. - General Observation - MISSING TILES 20%
520.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - BROKEN MISSING REBAR
598.8 ft. - Surface Reinforcement Corroded, from 09 to 02 o'clock, within 8 inches of joint: YES
601.7 ft. - General Observation - MISSING TILES 60%
611.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES
648.3 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES - BROKEN REBAR
654.7 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR
| Distance | Code | Observation |
|---|---|---|
| 2 | SAM | SEVERE AGG |
| 214.4 | MGO | MISSING TILES 70% |
| 462.2 | MGO | MISSING TILES 30% |
| 660.1 | MGO | MISSING TILES 100% FINISH |
| 660.2 | MGO | MH CONN ACTIVE 9:00 |
| 660.7 | AMH | 2:40AM |
| 303.8 | SRC | CORRODED BROKEN MISSING |
| 2 | SRC | CIRCUM & LONG REBAR |
| 282.9 | MGO | MISSING TILES 30% |
| 290.6 | SRC | — |
| 598.8 | SRC | — |
| 238.8 | MGO | MISSING TILES 70% |
| 660.1 | SAM | SEVERE AGG |
| 520.7 | SRC | BROKEN MISSING REBAR |
| 0 | MWL | — |
| 660.2 | MGO | MH CONN ACTIVE 3:00 |
| 232.9 | SRC | — |
| 445.2 | MGO | MISSING TILES 10% |
| 42.8 | SRC | BROKEN REBAR |
| 439.3 | SRC | BROKEN MISSING REBAR |
| 199.2 | SRC | — |
| 2 | MGP | LONG REBAR |
| 219.7 | SRC | — |
| 341 | MGO | MISSING TILES 30% |
| 316.4 | MGO | MISSING TILES 10% |
| 129.6 | MGO | MISSING TILES 20% |
| 196 | SRC | MISSING REBAR |
| 601.7 | MGO | MISSING TILES 60% |
| 0 | MGO | MH CONN ACTIVE 3:00 |
| 0 | AMH | 1:30AM |
| 252.1 | SRC | BROKEN MISSING REBAR |
| 0 | MGO | MISSING TILES 100% 9:00 TO 3:00 START |
| 660.1 | SRC | LONG & CIRCUM REBAR |
| 148.9 | MGO | MISSING TILES 50% |
| 648.3 | SRC | BROKEN REBAR |
| 367.1 | MGO | MISSING TILES 10% |
| 654.7 | SRC | CORRISON BEYOUND REBAR |
| 34.4 | SRC | POSSIBLE MISSING REBAR |
| 27.3 | SRC | LONG REBAR |
| 199.6 | SRC | MISSING & BROKEN REBAR |
| 434.9 | MGO | MISSING TILES 30% |
| 660.1 | SRC | MISSING BROKEN REBAR |
| 498.2 | SRC | — |
| 21.7 | SRC | POSSILE MISSING REBAR |
| 104.3 | MGO | MISSING TILES 30% |
| 0 | MWM | — |
| 516.8 | MGO | MISSING TILES 20% |
| 611.1 | SRC | — |