Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2015, 09:15 AM
  • 02 0125_02 0124_11172015_Manual.mp4

Date
11/17/2015
W/O
0541158
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02426
Time
1:15 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6639
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Capital Improvement Program Assesment
Project
20151116MDM_DOWNEY_BELLFLOWER_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
02 0125
Downstream MH
02 0124
Dir. of Survey
Downstream
Length Surveyed
268.5 ft.
Total Length
268.5 ft.
Structural Index
3
Structural Quick
5B3J
Structural Rating
244
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
244
Pipe schematic from manhole 02 0125 to 02 0124
MH: 02 0125MH: 02 0124downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:40AM2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES2 ft. MGO - General Observation - MISSING TILES 45% START 8:00 TO 4:002 ft. MGO - General Observation - MAG COAT 30% START18.7 ft. MGP - General Photograph30.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR35.9 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR START48.5 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish55.8 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM59.6 ft. MGO - General Observation - 25% MISSING TILES67 ft. SRV - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - LOMG & CIRCUM90 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCYM108.7 ft. SRV - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM119.1 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM141.9 ft. SRV - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM158.3 ft. MGP - General Photograph162.8 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM191.5 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG199.2 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM221.1 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG249.7 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM254.7 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM261 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM268.1 ft. MGO - General Observation - MAG COAT 30% FINISH268.1 ft. MGO - General Observation - MISSING TILES 45% FINISH268.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS OF MISSING TILES268.1 ft. MGO - General Observation - MH CONN ACTIVE 9:00268.1 ft. MGO - General Observation - MH CONN ACTIVE 9:00268.5 ft. AMH - Downstream Manhole, Survey Ends - 3:15AM

Observation photos (21)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

  • General Observation - MISSING TILES 45% START 8:00 TO 4:00

    2 ft. - General Observation - MISSING TILES 45% START 8:00 TO 4:00

  • General Observation - MAG COAT 30% START

    2 ft. - General Observation - MAG COAT 30% START

  • General Photograph

    18.7 ft. - General Photograph

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    30.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR START

    35.9 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR START

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

    55.8 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

  • General Observation - 25% MISSING TILES

    59.6 ft. - General Observation - 25% MISSING TILES

  • Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - LOMG & CIRCUM

    67 ft. - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - LOMG & CIRCUM

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCYM

    90 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCYM

  • Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM

    108.7 ft. - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM

    119.1 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - LONG CIRCUM

  • Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM

    141.9 ft. - Surface Reinforcement Visible, from 11 to 12 o'clock, within 8 inches of joint: YES - CIRCUM

  • General Photograph

    158.3 ft. - General Photograph

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM

    162.8 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG

    191.5 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

    199.2 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG

    221.1 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES - LONG

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM

    249.7 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

    254.7 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM

    261 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: YES - CIRCUM

Observations (31)

DistanceCodeObservation
141.9SRVCIRCUM
199.2SRVCIRCUM
30.1SRVLONG & CIRCUM REBAR
191.5SRVLONG
2SAVSEVERE AGG AREAS OF MISSING TILES
221.1SRVLONG
0MWM
108.7SRVCIRCUM
18.7MGP
254.7SRVCIRCUM
0MWL
268.1MGOMAG COAT 30% FINISH
67SRVLOMG & CIRCUM
268.5AMH3:15AM
0AMH2:40AM
48.5SRV
90SRVLONG & CIRCYM
59.6MGO25% MISSING TILES
268.1MGOMISSING TILES 45% FINISH
261SRVCIRCUM
249.7SRVLONG CIRCUM
119.1SRVLONG CIRCUM
2MGOMISSING TILES 45% START 8:00 TO 4:00
55.8SRVCIRCUM
268.1SAVSEVERE AGG AREAS OF MISSING TILES
268.1MGOMH CONN ACTIVE 9:00
162.8SRVCIRCUM
35.9SRVLONG & CIRCUM REBAR START
2MGOMAG COAT 30% START
268.1MGOMH CONN ACTIVE 9:00
158.3MGP

Properties (6)

custom_field_three
LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2015-11-17T01:15:16-08:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false