Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2015, 09:13 AM
  • 02 0127_02 0126_11172015_Manual.mp4

Date
11/17/2015
W/O
0541158
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02428
Time
1:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6639
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Capital Improvement Program Assesment
Project
20151116MDM_DOWNEY_BELLFLOWER_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
02 0127
Downstream MH
02 0126
Dir. of Survey
Downstream
Length Surveyed
305.4 ft.
Total Length
305.4 ft.
Structural Index
3
Structural Quick
563K
Structural Rating
207
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
207
Pipe schematic from manhole 02 0127 to 02 0126
MH: 02 0127MH: 02 0126downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - MH CONN ACTIVE 9:000 ft. AMH - Upstream Manhole, Survey Begins - 1:10AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN ACTIVE 3:008 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES8 ft. MGO - General Observation - MISSING TILES 40% START 8:00 TO 4:0028.3 ft. MGO - General Observation - MISSING TILES 20%62.2 ft. MGO - General Observation - MISSING TILES 20%86.1 ft. MGO - General Observation - MAG COAT 25%START117.1 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR124.4 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM POSSIBLE141.9 ft. MGO - General Observation - MISSING TILES 25% START177.8 ft. MGO - General Observation - MISSING TILES 40%START188.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCUM REBAR194.2 ft. MGO - General Observation - 2155 MISSING TILES213 ft. SRV - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR221.3 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR239.3 ft. MGO - General Observation - MISSING TILES 10%300.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR305.1 ft. MGO - General Observation - MAG COAT 30% FINISH305.1 ft. MGO - General Observation - MISSING TILES 40% FINISH305.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVBERE AGG AREAS OF MISSING TILES305.4 ft. AMH - Downstream Manhole, Survey Ends - 1:50AM

Observation photos (14)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

    8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

  • General Observation - MISSING TILES 40% START 8:00 TO 4:00

    8 ft. - General Observation - MISSING TILES 40% START 8:00 TO 4:00

  • General Observation - MISSING TILES 20%

    28.3 ft. - General Observation - MISSING TILES 20%

  • General Observation - MISSING TILES 20%

    62.2 ft. - General Observation - MISSING TILES 20%

  • General Observation - MAG COAT 25%START

    86.1 ft. - General Observation - MAG COAT 25%START

  • Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    117.1 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM POSSIBLE

    124.4 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM POSSIBLE

  • General Observation - MISSING TILES 25% START

    141.9 ft. - General Observation - MISSING TILES 25% START

  • General Observation - MISSING TILES 40%START

    177.8 ft. - General Observation - MISSING TILES 40%START

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCUM REBAR

    188.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG & CIRCUM REBAR

  • General Observation - 2155 MISSING TILES

    194.2 ft. - General Observation - 2155 MISSING TILES

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    221.3 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • General Observation - MISSING TILES 10%

    239.3 ft. - General Observation - MISSING TILES 10%

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    300.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

Observations (24)

DistanceCodeObservation
0MWM
221.3SRVLONG & CIRCUM REBAR
300.1SRVLONG & CIRCUM REBAR
305.1MGOMAG COAT 30% FINISH
28.3MGOMISSING TILES 20%
0MGOMH CONN ACTIVE 9:00
8SAVSEVERE AGG AREAS OF MISSING TILES
86.1MGOMAG COAT 25%START
213SRVCIRCUM REBAR
194.2MGO2155 MISSING TILES
124.4SRVCIRCUM POSSIBLE
117.1SRVCIRCUM REBAR
239.3MGOMISSING TILES 10%
8MGOMISSING TILES 40% START 8:00 TO 4:00
0AMH1:10AM
62.2MGOMISSING TILES 20%
305.4AMH1:50AM
177.8MGOMISSING TILES 40%START
305.1MGOMISSING TILES 40% FINISH
188.1SRVLONG & CIRCUM REBAR
0MWL
0MGOMH CONN ACTIVE 3:00
305.1SAVSEVBERE AGG AREAS OF MISSING TILES
141.9MGOMISSING TILES 25% START

Properties (6)

custom_field_three
LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2015-11-17T01:13:20-08:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false