Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2015, 10:07 AM
  • 02 0137_02 0136_11132015_Manual.mp4

Date
11/13/2015
W/O
0536410
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02439
Time
2:07 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6636
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
20151112MDM_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Upstream MH
02 0137
Downstream MH
02 0136
Dir. of Survey
Downstream
Length Surveyed
308.7 ft.
Total Length
308.7 ft.
Structural Index
3
Structural Quick
3A23
Structural Rating
36
O&M Index
2
O&M Quick
2C00
O&M Rating
42
Overall Index
2
Overall Quick
Overall Rating
78
Pipe schematic from manhole 02 0137 to 02 0136
MH: 02 0137MH: 02 0136downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:10AM0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area8.3 ft. MGO - General Observation - 27" VCP42.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE60.7 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - HAIRLINE60.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - HAIRLINE62.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE65.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN66.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE85.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - HAIRLINE114.2 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - 90% GREASE BLOCKAGE117.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - STUB122.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE157 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE163.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB167.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN174.6 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE174.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE216.3 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - 50% GREASE OPEN216.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start219.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - STUB242.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE242.8 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE246.2 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE268.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB272 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN283.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE283.8 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB296.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start296.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish308.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish308.3 ft. MGO - General Observation - MH CONN ACTIVE 21:00308.3 ft. MGO - General Observation - MH CONN STUB 9:00308.7 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (4)

  • General Observation - 27" VCP

    8.3 ft. - General Observation - 27" VCP

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    216.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB

    283.8 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - STUB

  • Deposits Attached Grease, 10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    296.4 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (35)

DistanceCodeObservation
296.4DAGS
66.8FLHAIRLINE
42.4FLHAIRLINE
157FLHAIRLINE
117.5TFCSTUB
242.8FLHAIRLINE
174.6FCHAIRLINE
283.8FLHAIRLINE
8.3MGO27" VCP
85.2FLHAIRLINE
163.3TFCSTUB
308.7AMH1:45AM
0AMH2:10AM
308.3DAGS
0MWL
242.8FCHAIRLINE
308.3MGOMH CONN ACTIVE 21:00
0MWM
122.3FLHAIRLINE
296.4DAGS
65.3TFOPEN
283.8TBCSTUB
167.3TFOPEN
62.3TFACTIVE
219.3TFCSTUB
114.2TFD90% GREASE BLOCKAGE
216.3TFD50% GREASE OPEN
216.3DAGS
174.6FLHAIRLINE
60.7FLHAIRLINE
60.7FLHAIRLINE
272TFOPEN
246.2FCHAIRLINE
268.5TFCSTUB
308.3MGOMH CONN STUB 9:00

Properties (6)

custom_field_three
HAIRLINES
custom_field_two
4
customer
LACSD
datetime
2015-11-13T02:07:52-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false