Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2015, 06:38 PM
Date
11/13/2015
W/O
0536163
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00349
PipeID
P02987
Time
10:38 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6637
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
COMMERCE
Loc. details
Railway
Location Code
L
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
20151113AM_DISTRICT_2_INTERCEPTOR_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Upstream MH
02 1415
Downstream MH
02 1416
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole 02 1415 to 02 1416
MH: 02 1415MH: 02 1416upstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON0.1 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES0.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES0.1 ft. MGO - General Observation - AIRLINE0.1 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO0.1 ft. LU - Alignment Up, 50 %2.1 ft. AMH - Downstream Manhole, Survey Begins - 10:40 AM2.1 ft. MWL - Water Level, 100 %of cross sectional area

Observation photos (5)

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • General Observation - AIRLINE

    2 ft. - General Observation - AIRLINE

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

    2.1 ft. - Survey Abandoned - VIEW OF THE UPLEG PIPE OF THE D/S SIPHON

Observations (8)

DistanceCodeObservation
2SAV
2.1MSAVIEW OF THE UPLEG PIPE OF THE D/S SIPHON
2SRV
2MGOAIRLINE
2SSS
2LU
0AMH10:40 AM
0MWL

Properties (6)

additional_info
VIEW OF THE UPLEG PIPE OF THE D/S SIPHON
custom_field_two
2
customer
LACSD
datetime
2015-11-13T10:38:38-08:00
documentation
MIRANDA, IGNACIO, MIRABAL, SHADLER
is_lateral_inspection
false