- Date
- 11/12/2015
- W/O
- 0536163
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00349
- PipeID
- P03007
- Time
- 1:38 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6632
- Sewer Name
- 02 DISTRICT #2 INTERCEPTOR TRUNK
- City
- COMMERCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- 20151112MDM_DISTRICT_2_INTERCEPTOR_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 02 1435
- Downstream MH
- 02 1432
- Dir. of Survey
- Downstream
- Length Surveyed
- 21.4 ft.
- Total Length
- 21.4 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 4124
- O&M Rating
- 12
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 02 1435 to 02 1432 Observation photos (2)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

10.8 ft. - General Photograph