Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 22, 2021, 05:28 AM
  • 02 0977_02 0976A_04212021_224202.mp4

Date
04/21/2021
W/O
886010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00279
PipeID
P03550
Time
10:28 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8740
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_886010_TV02334_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
18 in.
Upstream MH
02 0977
Downstream MH
02 0976A
Dir. of Survey
Downstream
Length Surveyed
277.6 ft.
Total Length
277.6 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
165
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
167
Pipe schematic from manhole 02 0977 to 02 0976A
MH: 02 0977MH: 02 0976Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 09772.1 ft. MGO - General Observation - MAG COAT2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start46 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"121.9 ft. TFI - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 5", 1", 6"277.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish277.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0976A277.6 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    46 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 5", 1", 6"

    121.9 ft. - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 5", 1", 6"

Observations (10)

DistanceCodeObservation
2.1MGOMAG COAT
46TSA
121.9TFI
277.6SAV
0MWM
2.1SAV
0MWL
277.6AMH02 0976A
0AMH02 0977
277.6MGOCONNECTION AT THE MH 3 OC'LOCK

Properties (7)

additional_info
630074042121201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-04-21T22:28:22-07:00
documentation
PROPIPE
is_lateral_inspection
false