02 0973_02 0972_04212021_232559.mp4
2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
38.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"
168.1 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 6", 2", 6"
376.2 ft. - Deposits Settled Fine, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 2.1 | SAV | — |
| 401.4 | MGO | CONNECTION AT THE MH 3 OC'LOCK |
| 38.7 | TB | — |
| 2.1 | MGO | MAG COAT |
| 401.4 | AMH | 02 0972 |
| 401.4 | MGO | CONNECTION AT THE MH 9 OC'LOCK |
| 168.1 | TBI | — |
| 280.2 | TFA | — |
| 0 | AMH | 02 0973 |
| 0 | MWM | — |
| 0 | MWL | — |
| 376.2 | DSF | — |
| 401.4 | SAV | — |
| 0 | MGO | CONNECTION AT THE MH 3 OC'LOCK CAPPED |
| 0 | MGO | CONNECTION AT THE MH 9 OC'LOCK |
| 2.1 | SSS | — |
| 401.4 | DSF | — |
| 401 | SSS | — |