Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2021, 05:46 AM
  • 01 1183_01 1182_03292021_225955.mp4

Date
03/29/2021
W/O
886342
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00225
PipeID
P02037
Time
10:46 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8708
Sewer Name
01 WILCOX AVENUE TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
WO_886342_TV01072_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
01 1183
Downstream MH
01 1182
Dir. of Survey
Downstream
Length Surveyed
255.5 ft.
Total Length
255.5 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
153
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
153
Pipe schematic from manhole 01 1183 to 01 1182
MH: 01 1183MH: 01 1182downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 11830 ft. MWM - Water Mark, 25 %of cross sectional area2.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"14.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"49 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"51.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"94.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"179.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"182 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"199.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish255.5 ft. AMH - Downstream Manhole, Survey Ends - 01 1182255.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK255.5 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
182TF
91.7TF
199.5TF
255.5SAV
11.6TF
94.3TFA
0MWL
179.5TF
255.5AMH01 1182
14.2TF
49TF
255.5MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH01 1183
51.7TF
0MWM
255.5MGOCONNECTION AT THE MH 3 OC'LOCK
2.4SAV

Properties (7)

additional_info
630074032921202
custom_field_three
aggregate visible
custom_field_two
3
customer
1
datetime
2021-03-29T22:46:58-07:00
documentation
PROPIPE
is_lateral_inspection
false