Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2021, 09:39 AM
  • 01 1174A_01 1174_03302021_025352.mp4

Date
03/30/2021
W/O
886342
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00225
PipeID
P02026
Time
2:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8708
Sewer Name
01 WILCOX AVENUE TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
WO_886342_TV01072_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
01 1174A
Downstream MH
01 1174
Dir. of Survey
Downstream
Length Surveyed
263.6 ft.
Total Length
263.6 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
159
Pipe schematic from manhole 01 1174A to 01 1174
MH: 01 1174AMH: 01 1174downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 1174A0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK2.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. MGO - General Observation - MAG COAT33.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"42.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES44.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"59.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"105.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"133.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"169.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"185.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.2 ft. RFC - Roots Fine Connection, at 10 o'clock223.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"259.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"263.6 ft. AMH - Downstream Manhole, Survey Ends - 01 1174263.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock,  , within 8 inches of joint: YES

    42.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
42.1DAGS
259.5TF
0MWL
223.5TF
44.1TF
0MWM
105.3TF
0AMH01 1174A
221.2TF
263.6AMH01 1174
169.3TF
121.5TF
59.5TF
133.7TF
2.7SAV
221.2RFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
185.6TF
2.7MGOMAG COAT
263.6SAV
33.6TF

Properties (7)

additional_info
630074032921202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-03-30T02:39:29-07:00
documentation
PROPIPE
is_lateral_inspection
false