- Date
- 03/30/2021
- W/O
- 886342
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00225
- PipeID
- P02025
- Time
- 3:00 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8708
- Sewer Name
- 01 WILCOX AVENUE TRUNK
- City
- BELL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_886342_TV01072_APR2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 24 in.
- Upstream MH
- 01 1174
- Downstream MH
- 01 1173
- Dir. of Survey
- Downstream
- Length Surveyed
- 359.4 ft.
- Total Length
- 359.4 ft.
- Structural Index
- 3
- Structural Quick
- 3M23
- Structural Rating
- 219
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 219
Pipe schematic from manhole 01 1174 to 01 1173 Observation photos (5)

2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: YES

71.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

172.6 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

304 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES