Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2021, 04:37 AM
  • C 0386_C 0385_04142021_215621.mp4

Date
04/14/2021
W/O
886022
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00142
PipeID
P09850
Time
9:37 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8728
Sewer Name
C JOINT OUTFALL C - UNIT 8D
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_886022_TV19067_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
114 in.
Upstream MH
C 0386
Downstream MH
C 0385
Dir. of Survey
Downstream
Length Surveyed
411.3 ft.
Total Length
411.3 ft.
Structural Index
3
Structural Quick
5I3O
Structural Rating
670
O&M Index
4
O&M Quick
4231
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
681
Pipe schematic from manhole C 0386 to C 0385
MH: C 0386MH: C 0385downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03862.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28.4 ft. IS - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES71.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"91.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.9 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start189.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"390.1 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES398.2 ft. IR - Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES406.2 ft. IR - Infiltration Runner, from 07 to 09 o'clock, within 8 inches of joint: YES411.3 ft. AMH - Downstream Manhole, Survey Ends - C 0385411.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK411.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish411.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish411.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (7)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

    28.4 ft. - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    152.9 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    390.1 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES

    398.2 ft. - Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 07 to 09 o'clock, within 8 inches of joint: YES

    406.2 ft. - Infiltration Runner, from 07 to 09 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
152.9SRV
0MWL
91.8TF
398.2IR
2.5SSS
28.4IS
0MWM
411.3AMHC 0385
390.1ID
406.2IR
411.3MGOCONNECTION AT THE MH 9 OC'LOCK
2.5SAP
411.3SAP
411.3SRV
0AMHC 0386
411.3SSS
71.7TFA
189.2TFA

Properties (8)

additional_info
630074041421201
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISIBLE/INFILTR
custom_field_two
2
customer
1
datetime
2021-04-14T21:37:38-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26643