Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 20, 2021, 06:20 AM
  • 02 0842_02 0841_04192021_233219.mp4

Date
04/19/2021
W/O
886157
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00296
PipeID
P03408
Time
11:20 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8736
Sewer Name
02 OLD RIVER SCHOOL ROAD RELIEF TRUNK, SECTION 1
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_886157_TV02088_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
18 in.
Upstream MH
02 0842
Downstream MH
02 0841
Dir. of Survey
Downstream
Length Surveyed
302.2 ft.
Total Length
302.2 ft.
Structural Index
3
Structural Quick
5I3K
Structural Rating
560
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
560
Pipe schematic from manhole 02 0842 to 02 0841
MH: 02 0842MH: 02 0841downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 08422.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start301.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish302.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish302.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0841302.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish302.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    41.3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWL
0MWM
2.5SSS
302.2SSS
301.5SAP
302.2AMH02 0841
0AMH02 0842
2.2SAP
302.2SRV
41.3SRV
302.2MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074041921202
custom_field_three
AGGREGATE PROJECTING/SPALLING/ REINFORCEMENT VISIB
custom_field_two
3
customer
1
datetime
2021-04-19T23:20:49-07:00
documentation
PROPIPE
is_lateral_inspection
false