Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 1, 2021, 05:13 AM
  • 05 0948_05 0947_03312021_222841.mp4

Date
03/31/2021
W/O
885825
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00481
PipeID
P06180
Time
10:13 PM
Certificate
885825
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8716
Sewer Name
05 MANCHESTER AVENUE PUMP TRUNK
City
HAWTHRONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_885825_TV05357_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
05 0948
Downstream MH
05 0947
Dir. of Survey
Downstream
Length Surveyed
439.4 ft.
Total Length
439.4 ft.
Structural Index
3
Structural Quick
3P00
Structural Rating
261
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
261
Pipe schematic from manhole 05 0948 to 05 0947
MH: 05 0948MH: 05 0947downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 09483.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"167.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - FILLED WITH DEBRI218.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - FILLED WITH DEBRI279.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"318.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"369.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"420.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"439.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish439.4 ft. AMH - Downstream Manhole, Survey Ends - 05 0947

Observation photos (1)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    279.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (17)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 9 OC'LOCK
420.5TFC
439.4CM
218.9TFC
279.5TB
167.8TFFILLED WITH DEBRI
270.6TFCFILLED WITH DEBRI
0MWL
369.4TF
120.5TFC
3.1CM
439.4AMH05 0947
0MWM
68.9TFC
17.9TFC
318.4TFC
0AMH05 0948

Properties (7)

additional_info
630074033121201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-31T22:13:34-07:00
documentation
PROPIPE
is_lateral_inspection
false