Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 16, 2021, 07:47 AM
  • B 1096_B 1095_04162021_013447.mp4

Date
04/16/2021
W/O
886008
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01124
PipeID
P13721
Time
12:47 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8732
Sewer Name
B JOINT OUTFALL B - UNIT 6G
City
ALHAMBRA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_886008_TV02344_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
B 1096
Downstream MH
B 1095
Dir. of Survey
Downstream
Length Surveyed
797.1 ft.
Total Length
797.1 ft.
Structural Index
3
Structural Quick
3_2_
Structural Rating
795
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
795
Pipe schematic from manhole B 1096 to B 1095
MH: B 1096MH: B 1095downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 10960 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start23.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"797.1 ft. AMH - Downstream Manhole, Survey Ends - B 1095797.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish797.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMHB 1096
797.1AMHB 1095
0MWM
0MWL
23.9TF
797.1SAP
3.1SAP
797.1SSS
3.1SSS

Properties (7)

additional_info
630074041521203
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-04-16T00:47:21-07:00
documentation
PROPIPE
is_lateral_inspection
false